HomeStore

Liberty LCU-N20ST Neutralizing Condensate Pump 115 V with Safety Switch & Media Cartridge

Product image 1
Product image 2

Liberty LCU-N20ST Neutralizing Condensate Pump 115 V with Safety Switch & Media Cartridge

Liberty LCU-N20ST Neutralizing Condensate Pump 115 V with Safety Switch & Media Cartridge

Liberty LCU-N20ST 115 Volt Neutralizing Condensate Pump

The Liberty LCU-N20ST is a specialized condensate pump designed for **neutralizing acidic condensate** from high-efficiency furnaces, boilers, and water heaters, while also handling non-acidic condensate from A/C, dehumidifiers, and ice machines. It features a **built-in safety switch**, dual inlet paths, and a replaceable **magnesium oxide media cartridge** to protect plumbing and the environment. 

Key Features & Benefits

  • Neutralizer Media Cartridge — granular magnesium oxide ) raises pH of acidic condensate before discharge.
  • Dual Inlet Options — three standard 1" inlets for non-acidic sources, plus a dedicated 1" and ¾" inlet for acidic condensate to prolong media life. 
  • Built-In Overflow Safety Switch — helps prevent overflows if tubing becomes blocked or pump fails
  • High-Impact ABS Tank — durable and corrosion-resistant housing. 
  • 3/8" Barbed / Threaded Discharge — simple connection to tubing (barbed) or threaded plumbing.
  • Removable Check Valve — for easy servicing or replacement. 
  • Fully Automatic & Quiet — thermally protected motor; vibration isolation pads included. 
  • Includes 20 ft Tubing — ready for field installation.

Specifications

Model LCU-N20ST
Horsepower / Volts / Amps 1/30 HP, 115 V, 1.5 A 
Max Fluid Temp 150 °F (65.5 °C) 
Max Head / Lift 20 ft 
Reservoir Capacity 2 US quarts
Weight Approx. 11 lbs 
Dimensions (H × L × W) 6.5 × 19× 5

Applications & Use Cases

  • Neutralizing and discharging acidic condensate from high-efficiency furnaces, boilers, or water heaters (up to 500,000 BTU input) 
  • Handling non-acidic condensate from air conditioners, dehumidifiers, ice machines via separate inlets 
  • Residential or light commercial HVAC systems where plumbing compatibility and pH protection are required

Installation & Maintenance Tips

  • Mount level on a wall or surface beneath the condensate source with access to inlets. 
  • Use the proper inlets: acid condensate should go into the dedicated inlet, while non-acidic condensate may use the general inlets. 
  • Check and replace the neutralizer media cartridge (part # K001898) annually or when outlet pH drops below ~5.0. 
  • Inspect check valves, tubing, and inlets for blockages regularly. 
  • If installed in freezing environments, drain lines and pump unit when idle. 

Note: Specifications are subject to change—always refer to the official Liberty Pumps documentation and installation manual for the most up-to-date data. 

$64.05

Original: $183.00

-65%
Liberty LCU-N20ST Neutralizing Condensate Pump 115 V with Safety Switch & Media Cartridge

$183.00

$64.05

Product Information

Shipping & Returns

Description

Liberty LCU-N20ST 115 Volt Neutralizing Condensate Pump

The Liberty LCU-N20ST is a specialized condensate pump designed for **neutralizing acidic condensate** from high-efficiency furnaces, boilers, and water heaters, while also handling non-acidic condensate from A/C, dehumidifiers, and ice machines. It features a **built-in safety switch**, dual inlet paths, and a replaceable **magnesium oxide media cartridge** to protect plumbing and the environment. 

Key Features & Benefits

  • Neutralizer Media Cartridge — granular magnesium oxide ) raises pH of acidic condensate before discharge.
  • Dual Inlet Options — three standard 1" inlets for non-acidic sources, plus a dedicated 1" and ¾" inlet for acidic condensate to prolong media life. 
  • Built-In Overflow Safety Switch — helps prevent overflows if tubing becomes blocked or pump fails
  • High-Impact ABS Tank — durable and corrosion-resistant housing. 
  • 3/8" Barbed / Threaded Discharge — simple connection to tubing (barbed) or threaded plumbing.
  • Removable Check Valve — for easy servicing or replacement. 
  • Fully Automatic & Quiet — thermally protected motor; vibration isolation pads included. 
  • Includes 20 ft Tubing — ready for field installation.

Specifications

Model LCU-N20ST
Horsepower / Volts / Amps 1/30 HP, 115 V, 1.5 A 
Max Fluid Temp 150 °F (65.5 °C) 
Max Head / Lift 20 ft 
Reservoir Capacity 2 US quarts
Weight Approx. 11 lbs 
Dimensions (H × L × W) 6.5 × 19× 5

Applications & Use Cases

  • Neutralizing and discharging acidic condensate from high-efficiency furnaces, boilers, or water heaters (up to 500,000 BTU input) 
  • Handling non-acidic condensate from air conditioners, dehumidifiers, ice machines via separate inlets 
  • Residential or light commercial HVAC systems where plumbing compatibility and pH protection are required

Installation & Maintenance Tips

  • Mount level on a wall or surface beneath the condensate source with access to inlets. 
  • Use the proper inlets: acid condensate should go into the dedicated inlet, while non-acidic condensate may use the general inlets. 
  • Check and replace the neutralizer media cartridge (part # K001898) annually or when outlet pH drops below ~5.0. 
  • Inspect check valves, tubing, and inlets for blockages regularly. 
  • If installed in freezing environments, drain lines and pump unit when idle. 

Note: Specifications are subject to change—always refer to the official Liberty Pumps documentation and installation manual for the most up-to-date data. 

Liberty LCU-N20ST Neutralizing Condensate Pump 115 V with Safety Switch & Media Cartridge | Big Frog Supply